Skip to main content

Workspace ONE UEM Intelligent Hub for Linux Release Notes

What's New in the Release Notes

Workspace ONE Intelligent Hub for Linux Release Notes describes the new features and enhancements in each release. This page contains a summary of the new capabilities, issues that have been resolved, and known issues that have been reported in each release over the last 12 months.

Workspace Intelligent Hub for Linux 24.06 - July 2024

  • New Features
  • Minimum Requirements
  • Resolved Issues
  • Known Issues

New Features

  • We are introducing Linux Application (App) Management. App Management provides the ability to manage applications on enrolled Linux endpoints. This includes installing, updating, and removing native applications by uploading .deb or .rpm files into Workspace ONE UEM.

Minimum Requirements

  • Testing and Customer Impact

Take advantage of these updates by meeting the minimum requirements and downloading Workspace ONE Intelligent Hub 24.06 for Linux.

The following are the Minimum Requirements for Workspace ONE Intelligent Hub for Linux.

  • Workspace ONE UEM 2406 running in a shared SaaS environment.

  • Workspace ONE UEM 2210 running in a dedicated SaaS environment, enabled with the new Control Plane.

Note: Workspace ONE UEM for Linux is not currently available for on-premise installations.

Resolved Issues

  • LAGNT-ID Num

Known Issues

  • We haven’t identified any notable known issues in this release. If you’re facing any problems, feel free to reach out to our support team.

Workspace Intelligent Hub for Linux 24.03 - April 2024

  • New Features
  • Minimum Requirements
  • Resolved Issues
  • Known Issues

New Features

  • SAML support has been added for CLI Enrollment.

For enrollments executed using the command line, the Intelligent Hub can now pop a browser to capture a user’s enrollment credentials if the Workspace ONE UEM Organization Group is configured for integrated, modern authentication. This removes a
limitation that has been present since the first release of the Intelligent Hub for Linux and minimizes the need for utilizing web enrollment to enroll users. This functionality requires either Firefox or Chrome be installed on the device.

  • Support 64-bit on ARM has been added.

New installers are available for 64-bit operating systems (OS) running on the ARM chipset. This includes support for virtual machines running on M-chip based Apple Mac devices and any other ARM hardware running a 64-bit OS.

  • Sensors in User Context are now available.

Workspace ONE Sensors can now be executed in the user context on a Linux device in addition to the existing option of running them in the system context. Now, this is like Mac and Windows that provide both options. The drop-down to select the execution context is in the definition of the sensor in Workspace ONE UEM starting with 2402.

  • Added the option for an admin to disable private key encryption.

  • Added support to validate iptables for fetching the firewall status.

  • Removed the sudo requirement from the enrollment command.

  • Added support for web enrollment using the flatpak installed browser.

Minimum Requirements

  • Testing and Customer Impact

Take advantage of these updates by meeting the minimum requirements and downloading Workspace ONE Intelligent Hub 24.03 for Linux.

The following are the Minimum Requirements for Workspace ONE Intelligent Hub for Linux.

  • Workspace ONE UEM 2310 running in a shared SaaS environment.

  • Workspace ONE UEM 2210 running in a dedicated SaaS environment, enabled with the new Control Plane.

Note: Workspace ONE UEM for Linux is not currently available for on-premise installations.

Resolved Issues

  • LAGNT-910 – Fix intermittent sample deserialization error while parsing date in non ISO formats.

  • LAGNT-916 - Remove sudo requirement from the enrollment command.

  • LAGNT-918 – Resolve log directory permissions errors after unenroll and enroll using ws1Hubutil.

  • LAGNT-921 - Add enrollment in progress check to avoid multiple enrollment attempt.

  • LAGNT-922 - Remove Hub restart after each feature flag value change.

  • LAGNT-975 - Support for Wi-Fi profile using password with additional special characters.

  • LAGNT-976 – Fix Assist for Linux button missing issue.

  • LAGNT-977 - Linux agents not consistently receiving auto-upgrade command.

  • LAGNT-1034 - Reduce number of log entries by AWCM on network failure.

Known Issues

  • We haven’t identified any notable known issues in this release. If you’re facing any problems, feel free to reach out to our support team.

Workspace Intelligent Hub for Linux 23.10 - December 2023

  • New Features
  • Minimum Requirements
  • Resolved Issues
  • Known Issues

New Features

  • We enabled the following commands:

    • Device Wipe – In addition to Enterprise Wipe which unenrolls, uninstalls the Hub, and removes any content pushed down with Workspace ONE UEM, Device Wipe provides a more extensive wipe, typically in response to a lost or stolen device. Device Wipe emulates a factory reset on the Linux device when invoked by the admin. This command removes apps, users, the user’s files/data, Wi-Fi connections, and other items to make the device unusable, requiring a new install of Linux.

    • Device Reboot – This command reproduces the effect of powering the device off and on again.

  • Added a symbolic link to ws1HubUtil so that the device side user no longer needs to change directory in order to execute.

  • We removed the sudo requirement in ws1HubUtil for status and version commands.

  • Now, ws1HubUtil explicitly checks for the commands that require sudo, providing more security and better error handling.

Minimum Requirements

  • Testing and Customer Impact

Take advantage of these updates by meeting the minimum requirements and downloading Workspace ONE Intelligent Hub 23.10 for Linux.

The following are the Minimum Requirements for Workspace ONE Intelligent Hub for Linux.

  • Workspace ONE UEM 2310 running in a shared SaaS environment.

  • Workspace ONE UEM 2210 running in a dedicated SaaS environment, enabled with the new Control Plane.

Note: Workspace ONE UEM for Linux is not currently available for on-premise installations.

Resolved Issues

  • LAGNT-706 - Web enrollment does not complete when enrolling to serial number registered device organization group.

  • LAGNT-777 - Update to latest version of SQLite.

  • LAGNT-786 - Default to higher Puppet version if latest version is unsuccessful instead of 5.

  • LAGNT-794 - Add Priority field in Debian control file.

  • LAGNT-798 - Improve Remove Action for Apps.

  • LAGNT-802 - Remove triggering profile list sample after profile install.

  • LAGNT-804 - Application packages are intermittently unable to download.

  • LAGNT-808 - Remove ApplicationType field in the app list sample.

  • LAGNT-815 - Token Based Authentication not properly prompting for token when using prompts.

  • LAGNT-818 - Support Two Factor Token Authentication for Linux Hub enrollment.

  • LAGNT-822 - Improve remove /usr/bin/ws1HubUtil error message during Hub removal.

  • LAGNT-823 - Replace ioutil package.

  • LAGNT-824 - Hub does not process apps when fetching the profile resource is unsuccessful.

  • LAGNT-825 - Remove usage of c libraries in processutil.

  • LAGNT-870 - Include Privacy Statement Path in CLI after enrollment.

  • LAGNT-872 - Puppet Install via gem fails in CentOS 9.

  • LAGNT-879 - Misspelling of enroll in ws1HubUtil help text.

  • LAGNT-893 - Certificate details not showing up in Device Details.

  • LAGNT-895 - Hub version validation is sometimes unsuccessful with ESR upgrade.

Known Issues

  • We haven’t identified any notable known issues in this release. If you’re facing any problems, feel free to reach out to our support team.

Workspace Intelligent Hub for Linux 23.04.1 - May 2023

  • New Features
  • Minimum Requirements
  • Resolved Issues
  • Known Issues

New Features

  • Introduced new WS1HubtUtil command line options.

Added more device side command line options to improve troubleshooting and enhance end user visibility.

  • Added Root Cert Deployment to the Browser Cert Store.

Now, when using Network Security Services (NSS) libraries, Workspace ONE UEM writes a root cert to Linux devices using Firefox and Chromium based browsers. NSS libraries are a prerequisite. Necessary components are automatically installed when using the Workspace ONE Intelligent Hub installer.

  • Now, private keys are encrypted by default

When private keys are generated for Linux devices, they will be AES256 encrypted by default using the password configured in the certificate.

  • Enabled the Device Lock command.

Use this command to lock a selected device, making it unusable until it's unlocked. Any signed in user must reauthenticate. If the user's credentials are valid, then they can log in.

Note: This feature requires Workspace ONE UEM 2304. Workspace ONE UEM 2304 is scheduled for release early summer 2023.

Minimum Requirements

  • The following are the Minimum Requirements for Workspace ONE Intelligent Hub for Linux.

    • Workspace ONE UEM 2206 running in a shared SaaS environment.

    • Workspace ONE UEM 2206 running in a dedicated SaaS environment, enabled with the new Control Plane.

Note: Workspace ONE UEM for Linux is not currently available for on-premise installations.

Resolved Issues

  • LAGNT-652 - Parsing cert common name fails.

  • LAGNT-657 - Improve Hub stop service.

  • LAGNT-658 - After enrollment, trigger Beacon/Sample immediately.

  • LAGNT-659 - Update Golang to 1.19 and update opensource packages.

  • LAGNT-663 -Wi-Fi profile install fails if password or SSID has a space or quote.

  • LGANT-666 - Linux Web Enrollment fails when running installer from the UI.

  • LAGNT-700 - Hub Service crashes when a remove profile command is sent for a profile that’s not installed.

  • LAGNT-709 – Certificate installation fails if its name has double quotes in it.

  • LAGNT-718 – Certificate renewal profile isn’t getting installed.

  • LAGNT-720 - Profile with certificate and custom config payload fails to install.

  • LAGNT-732 – Hub fails to identify if a device has network when host is behind a proxy.

  • LAGNT-736 – Add support in certconfig yaml file to support custom platforms.

  • LAGNT-760 – Wi-Fi profile fails when payload includes special characters

  • LAGNT-761 - Intermittent custom config failures while processing multiple profiles.

  • LAGNT-762 – Hub fails to process already removed profile actions.

  • LAGNT-769 - Updated agent setting profile installation causes hub to hang.

  • LAGNT-780 – High CPU usage post updating Hub to version 23.04.0.3.

  • LAGNT-781 – Hub auto upgrade failing with 23.04.0.3.

Known Issues

  • We haven’t identified any notable known issues in this release. If you’re facing any problems, feel free to reach out to our support team.

Workspace Intelligent Hub for Linux 22.06 - September 2022

  • New Features
  • Minimum Requirements
  • Resolved Issues
  • Known Issues

New Features

  • Now, Puppet open source is only required for processing custom configuration profiles. Dependencies on Wi-Fi or credentials payloads are no longer applicable.

  • Enhanced automated Hub upgrades. IT administators can enable Hub upgrades to occur automatically when new versions are released.

  • Implemented additional sensor triggers. Now, IT administrators have the option to trigger a sensor based on login, logout, startup, or network changes on enrolled Linux devices.

  • Added disk encryption detection. Workspace ONE identifies if full disk encryption (using LUKS) is enables on enrolled Linux devices.

  • Now, the Application tab in Devices Details shows desktop applications that are installed and version information on enrolled Linux-based endpoints.

  • Introduced web enrollment. A web-based wizard has been added to streamline downloading and enrollment of Workspace One Intelligent Hub for Linux. The wizard supports integrated authentication which allows Workspace ONE Access, SAML, or other integrated, modern authentication to be used for enrolling a Linux device in Workspace ONE UEM.

Minimum Requirements

  • The following are the Minimum Requirements for Workspace ONE Intelligent Hub for Linux.

    • Workspace ONE UEM 2206 running in a shared SaaS environment.

    • Workspace ONE UEM 2206 running in a dedicated SaaS environment, enabled with the new Control Plane.

Note: Workspace ONE UEM for Linux is not currently available for on-premise installations.

Resolved Issues

  • LAGNT-564 - App sample is missing app size info.

  • LAGNT-568 - Sensor definition with trigger type ScheduleAndEvent are not handled.

  • LAGNT-571 - Failure happens while processing deactivated profile.

  • LAGNT-573 - Uninstall profile status does not update.

  • LAGNT-581 - Unenroll command fails when the device record is deleted in console.

  • LAGNT-583 - Firewall status fails when ufw and firewalld exist.

  • LAGNT-594 - Linux web enrollment fails due to Firefox being installed via Snap.

  • LAGNT-595 - Wi-Fi Profile fails in DSM flow as Wi-Fi interface name is not populated.

  • LAGNT-606 - Cert based WI-FI profile fails due to path construction.

  • LAGNT-619 - Hub crashes when there are no Snaps installed or Snapcraft tools are not installed.

Known Issues

  • We haven’t identified any notable known issues in this release. If you’re facing any problems, feel free to reach out to our support team.

Download Instructions

  • Prior Version is Installed: The application seamlessly updates over the existing application version without disrupting device enterprise functionality. Manually install the new version on the enrolled device.

  • Prior Version is Not Installed: Direct end users to enroll using web enrollment where the Workspace ONE Intelligent Hub is automatically downloaded. The appropriate installer can be downloaded directly. For more information and instructions, see Enroll Your Linux Devices.

Support Contact Information

To receive support, either submit a ticket via the My Workspace ONE portal or call your local support line.

Was this page helpful?

Provide feedback for this topic

Was this topic helpful?

Please do not include any personal or confidential information.

Generating link…