You use the update-with-zip-24.12.1.0.hzn script to perform an offline upgrade of the existing Omnissa Access virtual appliance to the 24.12.1.0 version.
Note: This topic refers to the latest version, 24.12.1.0. The procedure for upgrading to any 24.12.x version is the same.
Important: You cannot perform a fresh install of Omnissa Access 24.12.x. Instead, you perform an offline upgrade to Omnissa Access 24.12.x.
Prerequisites
-
Perform the general offline-upgrade prerequisites. See Prerequisites for an Omnissa Access Offline Upgrade.
-
From a local computer, go to the Omnissa Customer Connect page and select the Download option to search for and download the two Omnissa Access 24.12.1.0 upgrade files
update-with-zip-24.12.1.0.hznandws1access-24.12.1.0-49efda362374f8d76a5a23fecc282b330acfe913-updaterepo.zip.
Procedure
-
Log in to the Omnissa Access appliance as the root user.
-
Navigate to directory with enough space to download the files.
The recommended location for saving the files is
/var/tmp. -
Download the
update-with-zip-24.12.1.0.hznfile. -
Download the
ws1access-24.12.1.0-49efda362374f8d76a5a23fecc282b330acfe913-updaterepo.zipfile.Verify that at least 5 GB of disk space are available on the primary root partition of the virtual appliance after copying the 24.12.1.0 upgrade files to the appliance.
-
Type
chmod +x update-with-zip-24.12.1.0.hznto make the file executable. -
Run the
/var/tmp/update-with-zip-24.12.1.0.hzn -f /var/tmp/ws1access-24.12.1.0-updaterepo.zipcommand to upgrade to 24.12.1.0.-f upgradeFilePath Upgrade the appliance using upgradeFilePath. upgradeFilePath must be an absolute path.
When you upgrade nodes in a cluster, in the first node that you upgrade, enter y to reindex the indices. When you upgrade the other nodes in the cluster, enter n. For a single node upgrade, the setting is y by default.Required -r Reboot after upgrade. Optional -h Displays the script usage. Optional -
If you did not use the
-roption with the script, restart the virtual appliance after the upgrade is complete.rebootIf the appliance is in a cluster, upgrade the other nodes one at a time.
-
After you upgrade all the nodes in your Omnissa Access deployment, use the diagnostics dashboard to monitor system information health.
-
Log in to the Omnissa Access console.
-
Select Monitor > Resiliency.
-
If your deployment consists of more than one Omnissa Access appliance, select the appliance you want to monitor.
-
Check the status of the various services.
-
Was deze pagina nuttig?